Biological Safety Cabinets

NuAire Biological Safety Cabinets provide personnel, product and/or environmental protection when looking to obtain optimum control over product quality while reducing the potential for exposure. Ergonomic Biosafety Cabinet design improves laboratory safety practices and process accuracy.

Choose NuAire class I biological safety cabinets where only personal protection is required.

  • LabGard ES (Energy Saver) NU-813 Bench Top Class I Containment Cabinet
  • LabGard ES (Energy Saver) NU-819 Bench Top Class I Vented Enclosure

NuAire Class II, Type A2 Biological Safety Cabinets provide personnel, product, and environmental protection through 30% exhausted / 70% recirculated airflow to minimize cross-contamination of low to moderate risk biologicals in the absence of volatile toxic chemicals.

  • CellGard ES (Energy Saver) HD (Hazardous Drug) NU-481 Class II, Type A2 Biosafety Cabinet
  • CellGard ES (Energy Saver) NU-475 Class II, Type A2 Biosafety Cabinet
  • CellGard ES (Energy Saver) NU-477 Class II, Type A2 Biosafety Cabinet
  • CellGard ES (Energy Saver) NU-480 Class II, Type A2 Biosafety Cabinet
  • LabGard ES (Energy Saver) NU-425 Class II, Type A2 Biosafety Cabinet
  • LabGard ES (Energy Saver) NU-437 Class II, Type A2 Biosafety Cabinet
  • LabGard ES (Energy Saver) NU-440 Class II, Type A2 Biosafety Cabinet

NuAire Class II, Type B1 Biological Safety Cabinets provide personnel, product, and environmental protection by exhausting 70% of airflow. B1 Cabinets may be used for work treated with minute quantities of volatile toxic chemicals and trace amounts of radionuclides required as an adjunct to microbiological studies if work is done in the direct exhausted portion of the cabinet, or if the chemicals or radionuclides will not interfere with the work when recirculated in the downflow air.

  • LabGard ES (Energy Saver) NU-427 Class II, Type B1 Biosafety Cabinet

NuAire Class II, Type B2 Total Exhaust Biological Safety Cabinets provide personnel, product, and environmental protection featuring downflow air drawn from within the laboratory or outside air. No downflow air is drawn from the cabinet exhaust air. All downflow and inflow air is exhausted through a HEPA filter without recirculation within the cabinet. The B2 Cabinet may be used for work with volatile toxic chemicals and radionuclides as required as adjuncts to microbiological studies.

  • LabGard ES (Energy Saver) NU-430 Class II, Type B2 Biosafety Cabinet
  • LabGard ES (Energy Saver) NU-435 Class II, Type B2 Biosafety Fume Hood

NuAire class III biosafety cabinet glove boxes provide a physical barrier between biological agents and personnel.

  • LabGard ES (Energy Saver) NU-704 Class III Biological Safety Cabinet